Mobile phone QR code
WeChat public account
HF-NECM series communication manager, as the communication bridge between the substation and the master station, is mainly used for equipment protocol conversion of power station, which realizes the data acquisition and forwarding under different protocols to meet relevant standards and specifications of power security, and the transmission of data from the substation to the dispatching system at all levels or the group's unified monitoring platform of operation and maintenance so as to seamlessly connect the equipment of various brands of manufacturers.
● With hardware independent watchdog circuit, software watchdog, monitoring and daemon process, etc.
● Support RS485, RS232, Ethernet, wireless 4G communication methods and so on.
● Support multi-channel different communication protocol acquisition and forwarding.
● Support serial port and Ethernet protocol clock synchronization, and SNTP timing services.
● Support historical data and log storage.
● With graphical client management tool, remote cloud management system.
● Large capacity real-time database system based on large capacity (more than 200,000 points) real-time database.
● Protocol multi-process independence. Each protocol process operates independently and does not influence each other.
● Redundant system architecture. The underlying system supports the two-hosts and two-network redundant system architecture, which can choose modes, such as single-host and single-network, single-host and double-network, double-host and double-network according to the needs.
● A set of cross-platform codes that supports running on different operating systems, such as Linux and Windows.
● Include rack-mounted, guide rail, wall-mounted, centralized and distributed types.
● Data acquisition and forwarding in wind power, photovoltaic, hydropower, thermal power and steam power stations, data transmission in operation and maintenance channels, telecontrol communication for power dispatching.
● Internal and dispatch communications in transformer substation and substation.
● Data acquisition, calculation and forwarding of intelligent power station.
● Data communication, etc. between on-site intelligent equipment and all kinds of instrument sensors of industries, such as petroleum, chemical, water affairs and heat supply.
● Flexible hardware configuration according to the actual operation on site.
● Direct configuration based on direct application of running configuration file as the input of configuration tool. The configuration maintenance can be carried out as long as it can run on site.
● The device definition between different projects and different intervals of the same project can be copied, imported and exported.
● The defined device can be directly exported as a template.
● Device template and definition files are standard Excel files, which can be viewed and modify easily.
● Configurations based on text files transfers backups.
● Cloud debugging used as quick solution to on-site problems.
Product photos |
![]() |
![]() |
![]() |
Model |
HF-NECM302 | HF-NECM201 | HF-NECM101 |
Hardware configuration |
Intel Celeron 2980 U dominant frequency, 1.6GHz, dual core, |
Cortex A8 dominant frequency 800MHz |
Cortex M4, dominant frequency 168MHz |
Network interface |
10/100/1000Mbps x 6 | 10/100Mbps x 4 | 10/100Mbps x 2 |
Serial port |
RS-232/485 x 8 (terminal wiring), 2KV isolation, surge protection |
RS-485 x 5, RS-232/485 x 1 (Terminal wiring), 2KV isolation, surge protection |
RS-485 x 8 (terminal wiring), 2KV isolation, surge protection |
Power supply |
88V~370VDC85V~265VAC | 12V-24V DC | 5V DC |
Size |
WHD:440mm x 280mm x 45mm | WHD:185mm x 40mm x 125mm | WHD:185mm x 40mm x 125mm |
Installation mode |
19 in., 1U rack-mounted |
Wall-mounted (guide rail) |
Wall-mounted (guide rail) |
Working temperature |
-25℃~+55℃ | -45℃~+70℃ | -45℃~+70℃ |
Optical port |
- | - | 10/100Mbps x 2 |
Optional interface |
IRIG-B x 1 | - | - |
Common access protocol |
Common roll-out protocol |
Specific protocol |
|
Nanzi Ethernet 103 protocol |
Modbus network protocol |
Regional telecontrol 104 protocol |
Configurable 61850 access |
NARI serial port 103 protocol |
Modbus serial port protocol |
Regional telecontrol 101 protocol |
Modeling 61870 roll out |
NARI network 103 protocol |
Positive isolation client-side and server protocols |
CDT protocol |
It can match with OPC server of mainstream manufacturers |
NARI LFP protocol |
Meter DL645 97/07 master station |
Modbus-TCP protocol |
It can match with OPC client of mainstream manufacturers |
SIFANG serial port 103 protocol |
Wiscom Ethernet 103 |
Nanzi 103 protocol |
|
XJ serial port 103 protocol |
Tianzheng Future Ethernet 103 |
IEC60870-5-103 protocol |
|
XJ network 104 protocol |
Siemens 200/300/400/1200/1500 TCP protocol |
IEC60870-5-104 protocol |
|
Zhejiang 103 protocol |
Schneider M218 protocol |
Over the years, Huafu Juneng has provided new energy users with box-type substation measurement and control protection series products, which have been in stable operation in more than 2,000 new energy stations at home and abroad with more than 60,000 sets of equipment in operation. The first-class product quality and professional technical services have won the trust of most transformer partners and the recognition of power generation users. For the future development strategy, the company will continue to focus on communication and protection system solutions on site, take it as its responsibility to meet the intelligent operation and maintenance needs of users' power stations, and undertake installation and technical innovation services of box-type substation measurement and control devices and communication systems inside the new energy wind power station and PV power stations.